INTRODUCTION
Simulate the child conveyances to run in a irregular surface,after doing the repeated impact test,check and evaluate safety performance.
Two fixtures on handle can move in vertical and horizontal directions independently and such adjust the width to accommodate different types and sizes of products.
TEST PRINCIPLE
Position relevant test mass in the pram body.
Standard obstacles are mounted on the conveyor system so that the wheels on each side of the vehicle are lifted alternately. The vehicle shall pass over those obstacles a total of 72 000 times at a speed of 5 km/h ± 0.1 km/h.
APPLY TO
Wheeled child conveyances,strollers,carriages etc
FEATURES AND BENEFITS
1.Display mode : big touch screen display.
2.Dsiplay datas : speed ,distance of trip,time,etc.
3. Control mode : Independently developed advanced PLC program control.
4. Programmable control of test times, cycle test and interval time.
5. Double closed-loop control of speed to ensure the accuracy of speed.
6. Stroller handle fixing method : according to the standard requirements.
7. Special structure, ensure that the conveyor belt will never run off, there will be no carpet-belt phenomenon.
8. Simplex machine covers less land and makes less noise. It is especially suitable for office building. Type TN3018-II do not have this advantage.
9.The appearance of the machine is absolutely high-end, atmospheric and high-grade. The bottom is equipped with universal powerful wheels, which is convenient to move the whole, and can ensure that the machine does not go when running.
10.Multiple grating protection to avoid injury.
TECHNICAL PARAMETERS
1.Test station : two stations (Type TN3018-II) ; one (standard type)
2.The conveyor belt speed : 0~8.5 km/h,adjustable
3.Speed resolution : 0.01 km/h ,standard of ±0.1 km/h
4.Maximum loading : 100 kg
5.Work width : 1000 mm
6.Vertical height of arms : 0~500 mm,adjustable
7.Across the width of arms : 0~300 mm,adjustable
8.Aluminum obstacles : according to the standards
9.Power supply : AC220V / AC380V,50 Hz,3000W
10.Weight : 550 kg (TN3018-II) ; 450 kg (standard)
11.Dimension : 340×128×185 cm ; 185×128×180 cm (standard type)
STANDARDS
BS EN 1888-1:2018+A1:2022,BS EN 1888-2:2018,BS EN 1888-3:2024,ISO 31110,GB 14748,etc
Copyright @ TONNY INTERNATIONAL粤ICP备17109882号
E-mail : 15015204254@163.com
Providing international recognition test equipments, consumables, in addition also providing customers with total laboratory solutions and good service platform.
Safety Test Instruments R&D